Advanced usage instructions for the Independent JPEG Group's JPEG software |
|
========================================================================== |
|
|
|
This file describes cjpeg's "switches for wizards". |
|
|
|
The "wizard" switches are intended for experimentation with JPEG by persons |
|
who are reasonably knowledgeable about the JPEG standard. If you don't know |
|
what you are doing, DON'T USE THESE SWITCHES. You'll likely produce files |
|
with worse image quality and/or poorer compression than you'd get from the |
|
default settings. Furthermore, these switches must be used with caution |
|
when making files intended for general use, because not all JPEG decoders |
|
will support unusual JPEG parameter settings. |
|
|
|
|
|
Quantization Table Adjustment |
|
----------------------------- |
|
|
|
Ordinarily, cjpeg starts with a default set of tables (the same ones given |
|
as examples in the JPEG standard) and scales them up or down according to |
|
the -quality setting. The details of the scaling algorithm can be found in |
|
jcparam.c. At very low quality settings, some quantization table entries |
|
can get scaled up to values exceeding 255. Although 2-byte quantization |
|
values are supported by the IJG software, this feature is not in baseline |
|
JPEG and is not supported by all implementations. If you need to ensure |
|
wide compatibility of low-quality files, you can constrain the scaled |
|
quantization values to no more than 255 by giving the -baseline switch. |
|
Note that use of -baseline will result in poorer quality for the same file |
|
size, since more bits than necessary are expended on higher AC coefficients. |
|
|
|
You can substitute a different set of quantization values by using the |
|
-qtables switch: |
|
|
|
-qtables file Use the quantization tables given in the named file. |
|
|
|
The specified file should be a text file containing decimal quantization |
|
values. The file should contain one to four tables, each of 64 elements. |
|
The tables are implicitly numbered 0,1,etc. in order of appearance. Table |
|
entries appear in normal array order (NOT in the zigzag order in which they |
|
will be stored in the JPEG file). |
|
|
|
Quantization table files are free format, in that arbitrary whitespace can |
|
appear between numbers. Also, comments can be included: a comment starts |
|
with '#' and extends to the end of the line. Here is an example file that |
|
duplicates the default quantization tables: |
|
|
|
# Quantization tables given in JPEG spec, section K.1 |
|
|
|
# This is table 0 (the luminance table): |
|
16 11 10 16 24 40 51 61 |
|
12 12 14 19 26 58 60 55 |
|
14 13 16 24 40 57 69 56 |
|
14 17 22 29 51 87 80 62 |
|
18 22 37 56 68 109 103 77 |
|
24 35 55 64 81 104 113 92 |
|
49 64 78 87 103 121 120 101 |
|
72 92 95 98 112 100 103 99 |
|
|
|
# This is table 1 (the chrominance table): |
|
17 18 24 47 99 99 99 99 |
|
18 21 26 66 99 99 99 99 |
|
24 26 56 99 99 99 99 99 |
|
47 66 99 99 99 99 99 99 |
|
99 99 99 99 99 99 99 99 |
|
99 99 99 99 99 99 99 99 |
|
99 99 99 99 99 99 99 99 |
|
99 99 99 99 99 99 99 99 |
|
|
|
If the -qtables switch is used without -quality, then the specified tables |
|
are used exactly as-is. If both -qtables and -quality are used, then the |
|
tables taken from the file are scaled in the same fashion that the default |
|
tables would be scaled for that quality setting. If -baseline appears, then |
|
the quantization values are constrained to the range 1-255. |
|
|
|
By default, cjpeg will use quantization table 0 for luminance components and |
|
table 1 for chrominance components. To override this choice, use the -qslots |
|
switch: |
|
|
|
-qslots N[,...] Select which quantization table to use for |
|
each color component. |
|
|
|
The -qslots switch specifies a quantization table number for each color |
|
component, in the order in which the components appear in the JPEG SOF marker. |
|
For example, to create a separate table for each of Y,Cb,Cr, you could |
|
provide a -qtables file that defines three quantization tables and say |
|
"-qslots 0,1,2". If -qslots gives fewer table numbers than there are color |
|
components, then the last table number is repeated as necessary. |
|
|
|
|
|
Sampling Factor Adjustment |
|
-------------------------- |
|
|
|
By default, cjpeg uses 2:1 horizontal and vertical downsampling when |
|
compressing YCbCr data, and no downsampling for all other color spaces. |
|
You can override this default with the -sample switch: |
|
|
|
-sample HxV[,...] Set JPEG sampling factors for each color |
|
component. |
|
|
|
The -sample switch specifies the JPEG sampling factors for each color |
|
component, in the order in which they appear in the JPEG SOF marker. |
|
If you specify fewer HxV pairs than there are components, the remaining |
|
components are set to 1x1 sampling. For example, the default YCbCr setting |
|
is equivalent to "-sample 2x2,1x1,1x1", which can be abbreviated to |
|
"-sample 2x2". |
|
|
|
There are still some JPEG decoders in existence that support only 2x1 |
|
sampling (also called 4:2:2 sampling). Compatibility with such decoders can |
|
be achieved by specifying "-sample 2x1". This is not recommended unless |
|
really necessary, since it increases file size and encoding/decoding time |
|
with very little quality gain. |
|
|
|
|
|
Multiple Scan / Progression Control |
|
----------------------------------- |
|
|
|
By default, cjpeg emits a single-scan sequential JPEG file. The |
|
-progressive switch generates a progressive JPEG file using a default series |
|
of progression parameters. You can create multiple-scan sequential JPEG |
|
files or progressive JPEG files with custom progression parameters by using |
|
the -scans switch: |
|
|
|
-scans file Use the scan sequence given in the named file. |
|
|
|
The specified file should be a text file containing a "scan script". |
|
The script specifies the contents and ordering of the scans to be emitted. |
|
Each entry in the script defines one scan. A scan definition specifies |
|
the components to be included in the scan, and for progressive JPEG it also |
|
specifies the progression parameters Ss,Se,Ah,Al for the scan. Scan |
|
definitions are separated by semicolons (';'). A semicolon after the last |
|
scan definition is optional. |
|
|
|
Each scan definition contains one to four component indexes, optionally |
|
followed by a colon (':') and the four progressive-JPEG parameters. The |
|
component indexes denote which color component(s) are to be transmitted in |
|
the scan. Components are numbered in the order in which they appear in the |
|
JPEG SOF marker, with the first component being numbered 0. (Note that these |
|
indexes are not the "component ID" codes assigned to the components, just |
|
positional indexes.) |
|
|
|
The progression parameters for each scan are: |
|
Ss Zigzag index of first coefficient included in scan |
|
Se Zigzag index of last coefficient included in scan |
|
Ah Zero for first scan of a coefficient, else Al of prior scan |
|
Al Successive approximation low bit position for scan |
|
If the progression parameters are omitted, the values 0,63,0,0 are used, |
|
producing a sequential JPEG file. cjpeg automatically determines whether |
|
the script represents a progressive or sequential file, by observing whether |
|
Ss and Se values other than 0 and 63 appear. (The -progressive switch is |
|
not needed to specify this; in fact, it is ignored when -scans appears.) |
|
The scan script must meet the JPEG restrictions on progression sequences. |
|
(cjpeg checks that the spec's requirements are obeyed.) |
|
|
|
Scan script files are free format, in that arbitrary whitespace can appear |
|
between numbers and around punctuation. Also, comments can be included: a |
|
comment starts with '#' and extends to the end of the line. For additional |
|
legibility, commas or dashes can be placed between values. (Actually, any |
|
single punctuation character other than ':' or ';' can be inserted.) For |
|
example, the following two scan definitions are equivalent: |
|
0 1 2: 0 63 0 0; |
|
0,1,2 : 0-63, 0,0 ; |
|
|
|
Here is an example of a scan script that generates a partially interleaved |
|
sequential JPEG file: |
|
|
|
0; # Y only in first scan |
|
1 2; # Cb and Cr in second scan |
|
|
|
Here is an example of a progressive scan script using only spectral selection |
|
(no successive approximation): |
|
|
|
# Interleaved DC scan for Y,Cb,Cr: |
|
0,1,2: 0-0, 0, 0 ; |
|
# AC scans: |
|
0: 1-2, 0, 0 ; # First two Y AC coefficients |
|
0: 3-5, 0, 0 ; # Three more |
|
1: 1-63, 0, 0 ; # All AC coefficients for Cb |
|
2: 1-63, 0, 0 ; # All AC coefficients for Cr |
|
0: 6-9, 0, 0 ; # More Y coefficients |
|
0: 10-63, 0, 0 ; # Remaining Y coefficients |
|
|
|
Here is an example of a successive-approximation script. This is equivalent |
|
to the default script used by "cjpeg -progressive" for YCbCr images: |
|
|
|
# Initial DC scan for Y,Cb,Cr (lowest bit not sent) |
|
0,1,2: 0-0, 0, 1 ; |
|
# First AC scan: send first 5 Y AC coefficients, minus 2 lowest bits: |
|
0: 1-5, 0, 2 ; |
|
# Send all Cr,Cb AC coefficients, minus lowest bit: |
|
# (chroma data is usually too small to be worth subdividing further; |
|
# but note we send Cr first since eye is least sensitive to Cb) |
|
2: 1-63, 0, 1 ; |
|
1: 1-63, 0, 1 ; |
|
# Send remaining Y AC coefficients, minus 2 lowest bits: |
|
0: 6-63, 0, 2 ; |
|
# Send next-to-lowest bit of all Y AC coefficients: |
|
0: 1-63, 2, 1 ; |
|
# At this point we've sent all but the lowest bit of all coefficients. |
|
# Send lowest bit of DC coefficients |
|
0,1,2: 0-0, 1, 0 ; |
|
# Send lowest bit of AC coefficients |
|
2: 1-63, 1, 0 ; |
|
1: 1-63, 1, 0 ; |
|
# Y AC lowest bit scan is last; it's usually the largest scan |
|
0: 1-63, 1, 0 ; |
|
|
|
It may be worth pointing out that this script is tuned for quality settings |
|
of around 50 to 75. For lower quality settings, you'd probably want to use |
|
a script with fewer stages of successive approximation (otherwise the |
|
initial scans will be really bad). For higher quality settings, you might |
|
want to use more stages of successive approximation (so that the initial |
|
scans are not too large).
|
|
|